Minimum qualifications to be an electrician?
Page Previous  1, 2, 3, 4, 5, 6  Next
 
Post new topic   Reply to topic    Downsizer Forum Index -> Small Business Questions, Ideas and Advice
Author 
 Message
12Bore



Joined: 15 Jun 2008
Posts: 9089
Location: Paddling in the Mersey
PostPosted: Sun Mar 03, 13 4:00 pm    Post subject: Reply with quote
    

Nick wrote:
So, a real test. For a ring main in a garage including sockets for power tools and feezers, and strip lights, what cable is required?

Fire resistant.

Nick



Joined: 02 Nov 2004
Posts: 34535
Location: Hereford
PostPosted: Sun Mar 03, 13 4:01 pm    Post subject: Reply with quote
    


OtleyLad



Joined: 13 Jan 2007
Posts: 2737
Location: Otley, West Yorkshire
PostPosted: Sun Mar 03, 13 5:15 pm    Post subject: Reply with quote
    

Nick wrote:
So, a real test. For a ring main in a garage including sockets for power tools and feezers, and strip lights, what cable is required?

Is the garage attached to the house?
If it is attached to the house and you have spare room in your consumer unit then run a 2.5mm ring with a 32amp 32ma rcb for the power sockets, freezers, etc.
Run another 1.5 or 1mm radial circuit for the strip lights- an ordinary 6amp mcb would do on that.
If the garage is seperate I'd run an armoured cable to it from again a 32amp 32ma rcb in your house condumer unit. Put a smaller consumer unit in the garage (with the armoured canle to the isolating/main switch. From this smaller condumer unit run your ring and lights circuits as above.

OtleyLad



Joined: 13 Jan 2007
Posts: 2737
Location: Otley, West Yorkshire
PostPosted: Sun Mar 03, 13 5:15 pm    Post subject: Reply with quote
    

Nick wrote:
So, a real test. For a ring main in a garage including sockets for power tools and feezers, and strip lights, what cable is required?

Is the garage attached to the house?
If it is attached to the house and you have spare room in your consumer unit then run a 2.5mm ring with a 32amp 32ma rcb for the power sockets, freezers, etc.
Run another 1.5 or 1mm radial circuit for the strip lights- an ordinary 6amp mcb would do on that.
If the garage is seperate I'd run an armoured cable to it from again a 32amp 32ma rcb in your house condumer unit. Put a smaller consumer unit in the garage (with the armoured cable to the isolating/main switch. From this smaller consumer unit run your ring and lights circuits as above.

Last edited by OtleyLad on Sun Mar 03, 13 5:34 pm; edited 1 time in total

Nick



Joined: 02 Nov 2004
Posts: 34535
Location: Hereford
PostPosted: Sun Mar 03, 13 5:28 pm    Post subject: Reply with quote
    

Detached, and that's exactly what I've done. Yay.

OtleyLad



Joined: 13 Jan 2007
Posts: 2737
Location: Otley, West Yorkshire
PostPosted: Sun Mar 03, 13 5:35 pm    Post subject: Reply with quote
    

Nick wrote:
Detached, and that's exactly what I've done. Yay.


Something about brilliant minds?

Melli-Jane



Joined: 09 Mar 2011
Posts: 272
Location: East Sussex
PostPosted: Mon Mar 04, 13 2:15 pm    Post subject: Reply with quote
    

Hi - just saw this thread, my OH is looking into abandoning the NHS and retraining as an electrician - he's been looking at some of the providers but I don't think he has seen the OLCI. Could you possibly PM me with the course costs, please?

OtleyLad



Joined: 13 Jan 2007
Posts: 2737
Location: Otley, West Yorkshire
PostPosted: Fri Apr 26, 13 12:20 pm    Post subject: Reply with quote
    

After a hard week doing the Inspection and Testing module i heard this pm that i've passed all the exams and practicals. There's still Solar installations and electric boilers to do but it means I can now apply to join a 'competant person' scheme and get ready to finally earn some money as a proper sparky.
Too nackered to jump up and down but when i recover some serious celebration is called for.
If anyone needs a free range organic electrician, you know who to call...

12Bore



Joined: 15 Jun 2008
Posts: 9089
Location: Paddling in the Mersey
PostPosted: Fri Apr 26, 13 3:42 pm    Post subject: Reply with quote
    

Well done!

judith



Joined: 16 Dec 2004
Posts: 22789
Location: Montgomeryshire
PostPosted: Fri Apr 26, 13 4:05 pm    Post subject: Reply with quote
    

Congratulations. Definitely cause for celebration.

stumbling goat



Joined: 20 Jan 2009
Posts: 1990

PostPosted: Fri Apr 26, 13 4:20 pm    Post subject: Reply with quote
    

Congratulations OL.

sg

jamanda
Downsizer Moderator


Joined: 22 Oct 2006
Posts: 35056
Location: Devon
PostPosted: Fri Apr 26, 13 4:21 pm    Post subject: Reply with quote
    

Well done

markjadams



Joined: 06 May 2006
Posts: 109
Location: South West Wales
PostPosted: Fri Apr 26, 13 9:17 pm    Post subject: Reply with quote
    

Big well done from me, it is a hard slog glad you got there in the end.

Mark.

OtleyLad



Joined: 13 Jan 2007
Posts: 2737
Location: Otley, West Yorkshire
PostPosted: Tue Jun 04, 13 3:32 pm    Post subject: Reply with quote
    

I am joining the NICEIC 'competant person' scheme to be a qualified domestic installer. To do this they want to see 2 pieces of work that you have done (they come and inspect 2 new ones every year to see you are obeying the regs).
I went for a consumer unit replacement in our house and ordered a brand new split thing - it has 2 sets of 5 circuit breakers, each controlled by a RCD switch. Also it has 3 ordinary mcbs with no RCD.
So I took out the old CU and put in the new.
When it came to switch on every circuit except one tripped the RCDs!
Luckily I can temporaily link the circuits to the no-RCD protected mcbs so at least we can have some power. It has after all been operating fault free for years.
When I tested for continuity (to check all the wires are joined up) all were fine. But the IR test (test that the insulation is sound) failed all the circuits bar one.
Never mind it's a good thing for me to try and figure out and better I do it in my own home rather than at a customer's.
I tracked down the faulty line on the socket circuit, so thought I'd lift the floor boards and locate the exact location of the fault. What a nightmare!

Whoever re-wired the house was not a tidy person and worse they laid wires under the first floor in a single notch barely an inch deep - no trouble at all to bash a screw or nail through them if you felt like it. And there are 12 wires (plus 2 for the telephone) all squeezed together as they cross each joist. They were also run laying on the central heating water pipes.
The pic shows them after I separated them a little!

So I'm going to have to pull up a lot of wires and re-route through several holes in the joists - to spread them out.
Having found the fault I replaced the damaged wire and then connected the ring via a RCD - at least it does not trip now.
Only 6 more circuits to go. I can see this is going to end up taking a very long time...

RichardW



Joined: 24 Aug 2006
Posts: 8443
Location: Llyn Peninsular North Wales
PostPosted: Tue Jun 04, 13 5:05 pm    Post subject: Reply with quote
    

I am sure you know but just in case.

A really common reason for the rcd to trip in cases like this is due to the neutral being wired back to the wrong rcd on the split board or for some one to have tapped into a neutral mainly to add an extra light & when a split board is fitted the live & neutral end up on different rcd's.